- 8 -
INST 396 Jacuzzi® J-HN Series Heater V12-16
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life
A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do
not attempt to light the burner by hand
B. BEFORE OPERATING, smell all around the heater area for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS. Do not try to light any
appliance. Do not touch any electric switch, do not use any phone in your building. Immediately call your gas supplier
from a safe area away from the heater. Follow the gas suppliers instructions. If you cannot reach your gas supplier,
call the fire department.
C. If the gas valve is malfunctioning and not admitting gas to burner, don’t try to repair it, call a qualified service
technician. Force or attempted repair mat result in a fire or explosion.
D. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any gas control which has been under water
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this label
2. Turn Off all electrical power to the Heater
3. Do not attempt to light the burner by hand
4. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!, Follow “B” in the safety information above
on this label. If you don’t smell gas, go to the next step.
5. Turn on the water circulation pump.
6. Turn on the power to the heater and press the Pool/Spa button to select Pool or spa.
7. Set the thermostat to desired setting and the ON/OFF switch to the “ON” position.
8. The Heater will take approximately 125 seconds to complete ignition cycle. The heater will reattempt to ignite the
burner automatically repeating the final ignition sequence for a total of three (3) attempts before locking out system.
9. If the appliance does not operate, turn heater power supply off. Repeat instructions 5 to 7 above. If the appliance
still does not ignite, call your service technician
TO TURN OFF GAS TO HEATER
1. TURN OFF ALL ELECTRIC POWER TO THE HEATER IF SERVICE IS TO BE PERFORMED.
2. Turn off manual Gas tap in gas supply line prior to Heater

Questions and Answers: