32
Exiting Priming Mode
The system will automatically enter the normal heating mode and ltering at the end of the
priming mode, which lasts 4-5 minutes.
You can manually exit Priming Mode by pressing the “Back” button on the Priming Mode
Screen. Note that if you do not manually exit the priming mode as described above, the
priming mode will be automatically terminated after 4-5 minutes. Be sure that the pump(s)
have been primed by this time.
Once the system has exited Priming Mode, the top side panel will display the Main Screen,
but the display will not show the water temperature yet. This is because the system requires
approximately 1 minute of water owing through the heater to determine the water tem-
perature to display it.
10.5 Spa Behaviour
Pumps
On the Spa Screen, select a “Jets” button once to turn the pump on or o, and to shift be-
tween low and high speeds if equipped. If left running, the pump will turn o after a time-
out period of 30 minutes.
Non-Circ Systems
The low-speed of pump 1 runs when any other pump is on. If the swim spa is in Ready
Mode, Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the
swim spa temperature (polling) and then to heat to the set temperature if needed. When
the low-speed turns on automatically, it cannot be deactivated from the panel, however the
high speed may be started.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during ltration. The sys-
tem is factory-programmed with one lter cycle that will run in the evening (assuming the
time-of-day is properly set) when energy rates are often lower. The lter time and duration
are programmable. A second lter cycle can be enabled as needed. At the start of each lter
cycle, the pumps will run briey to purge the plumbing to maintain good water quality.