Page 12
4.2 DIP Switch Settings for Pool and Spa Combination
S1 DIP Switch # OFF ON
1 AUX1= any equipment AUX1= Pool Cleaner
2 AUX2= any equipment AUX2= Low Speed for a two-speed filter pump.
Filter pump circuit becomes High Speed.
3 NOT USED NOT USED
4 Heater cool down operates. Heater cool down disabled.
5 Normal operation Factory adjustment- when this switch is on,
temperature delays are eliminated and solar
temperature is displayed.
Do not leave this switch in the ON position.
6 Separate Pool and Spa heater. Sharing one heater for pool and spa.
7 No solar system installed. Air temperature
is displayed.
Changes air sensor to solar sensor. Air temperature
no longer displayed. Adjustable Freese Kit must be
added for freeze protection.
8 After thermostat setting has been
reached, heater will remain OFF for 3
minutes.
Heat Pump installed; after thermostat setting
has been reached, heater will remain OFF for 5
minutes.
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
4 3 2 1
4 3 2 1
RESET
SERVICE
TIME OUT
FILTER PUMP
AUX 1
AUX 2
AUX
3
A
UX
4
AUX 5
A
UX 6
SPA PUMP
AUTO
POOL HEATER
SPA HEATER
SOLAR
1
OFF
ON
3
4
5
6
7
8
2
1
2
3
4
S1
S2
S2 DIP Switch # OFF ON
1 The AquaLink RS will be able to control a
Solar Heating system (If a solar sensor is
connected to the solar sensor input).
The AquaLink RS will be able to control a Heat
Pump. (The AquaLink RS will not be able to control
a Solar Heating system.)
2 NOT USED
3 NOT USED
4 NOT USED