4.3 DIP Switch Settings for Pool or Spa Only
S1 DIP Switch # OFF ON
1 AUX1= any equipment AUX1= Pool Cleaner
2 AUX2= any equipment AUX2= Low Speed for a two-speed filter pump.
Filter pump circuit becomes High Speed.
3 AUX3= any equipment No change
4 Heater cool down operates. Heater cool down disabled.
5 Normal operation Factory adjustment- when this switch is on,
temperature delays are eliminated and solar
temperature is displayed.
Do not leave this switch in the ON position.
6 Spare No change
7 Spare No change
8 After thermostat setting has been reached,
heater will remain OFF for 3 minutes.
Heat Pump installed; after thermostat setting
has been reached, heater will remain OFF for 5
minutes.
S2 DIP Switch # OFF ON
1 The AquaLink RS will be able to control a
Solar Heating system (If a solar sensor is
connected to the solar sensor input).
The AquaLink RS will be able to control a Heat
Pump. (The AquaLink RS will not be able to
control a Solar Heating system.)
2 NOT USED
3 NOT USED
4 NOT USED
4.4 DIP Switch Settings for Heat Pump Installation
ThistableshowshowtoconfigurethesystemforSOLARPRIORITYorHEATPUMPPRIORITY.
DIP S2-1
GREEN 10-PIN
TERMINAL BAR
RS485 HEAT PUMP DESCRIPTION
OFF No sensor installed Not connected In this configuration there is no Solar Heating and no
Heat Pump. Extra AUX is available.
OFF Sensor installed Not connected In this configuration there is Solar Heating and there
is Solar Priority. There is no Heat Pump.
OFF Sensor installed Connected In this configuration there is Solar Heating and there
is Solar Priority. There is Heat Pump. There is Heat
Pump Priority.
ON No sensor installed Not connected In this configuration there is no Solar Heating. There
is a mechanically connected Heat Pump. There is
Heat Pump Priority (a limited implementation).
ON Sensor installed Not connected In this configuration there is no Solar Heating. There
is a mechanically connected Heat Pump. There is
Heat Pump Priority (full implementation).
ON Sensor installed Connected In this configuration there is no Solar Heating. There
is an RS485 controlled Heat Pump. There is Heat
Pump Priority.