Page 22
Section 5. Operating Instructions
Figure 26. Control Panel on the Power Pack
On/Off
Flow Salt
Output
Indicates level of chlorine
output production.
Each light represents a
20% increment of output
production.
Check salt level indicator
Indicates that there
is not enough fl ow
through the cell
WARNING
To avoid property damage, serious injury or death, do not operate the electrolytic cell without water circulation. A buildup of
fl ammable gasses which can result in FIRE OR EXPLOSION.
5.2 Turning Power Pack On/Off (Manually)
To turn the Jandy
®
AquaPure
®
Ei
TM
chlorine generating device on or off press the button.
NOTE: The power pack will only turn on and the cell will only produce chlorine when water fl ow is detected by the
fl ow switch.
5.3 Setting the Chlorine Output Level
When setting the chlorine output level you must consider the size of the pool, the amount of use the pool will be re-
ceiving and how hot the weather is. All these factors weigh greatly on the level of output needed. To adjust the output
level, follow these steps:
1. Turn the power pack on by pressing the
button.
2. Press the
button to reach the desired output level. The minimum setting is 20% (one amber light). The
output can be adjusted in increments of 20% up to 100%. If the OUTPUT button is pressed beyond 100%, the
output level setting will drop back to 20%.
Output Setting Amount of time cell will run
20% - one (1) light Cell will run two (2) min. every ten (10) min.
40% - two (2) lights Cell will run four (4) min. every ten (10) min.
60% - three (3) lights Cell will run six (6) min. every ten (10) min.
80% - four (4) lights Cell will run eight (8) min. every ten (10) min.
100% - five (5) lights Cell will run non-stop.
5.1 Control Panel