EasyManua.ls Logo

Janome 219S - Troubleshooting Common Issues; Troubleshooting: Needle Thread Breaks; Troubleshooting: Bobbin Thread Breaks; Troubleshooting: Needle Breaks

Janome 219S
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
q
w
e
y
r
t
u
SECTION 5. CARE OF YOUR MACHINE
Dismantling and Assembling
Shuttle Race Unit
Note :Turn off the power switch and/or unplug the
machine.
To dismantle shuttle race unit:
Raise the needle to its highest position and open the
hook cover.
Open the hinged latch of bobbin case and take it out of
the machine.
Open the hook race ring holders and remove the shuttle
race ring.
Remove the hook.
* Clean the hook race with a brush and a soft dry cloth.
q Bobbin case
w Shuttle race ring holder
e Shuttle race ring
r Shtuule
t Shuttle race
To assemble shuttle race unit:
Shuttle the hook by the center pin and fit it carefully
back into the shuttle race, forming a perfect circle
with the shuttle driver.
Attach the shuttle race ring making sure the bottom
pin fits into the notch.
Lock the shuttle race ring by turning the holders
back into position. Insert the bobbin case.
y Pin
u Notch
Cleaning the Feed Dog
Remove the needle and the presser foot.
Remove the needle plate set screw and remove
the needle plate.
With a brush, clean out dust and lint clogging the
feed dog teeth.
Reset the needle plate.
WARNING:
Turn off the power switch and/or unplug the machine
before cleaning the feed dog.