WWW.JASIC.CO.UK 16
Channel key
For the simple and eecve management of welding instrucons, the machine is equipped
with 64 channels for storage of general MIG/MAG, pulse MIG/MAG and double pulse MIG/
MAG welding modes. A channel stores a sequence of all parameters in a welding
instrucon. Take general MIG/MAG for example, a welding instrucon includes parameters
such as base metal type, gas type, wire type, operaon mode, pre-ow me, inial current, inial speed,
inial voltage, upslope me, peak current, peak speed, thickness of base metal, arc characterisc, peak
voltage, spot welding me, downslope me, crater current, crater speed, crater voltage and post-ow
me. All these parameters constute a process data channel or a channel for short. Channels are
indicated with channel numbers. The working channel means the channel being used currently.
To access the channel management mode: Press the channel key in standby mode, the channel LED will
be on, and the channel management mode can be accessed.
The machine when switched on will work in the channel last used before the machine was switched o
and this channel number will be displayed on the voltage column parameters display meter, by pressing
the channel key. At this me, users can change the working channel number by adjusng the knob.
To store and exit the channel management mode, press the channel key or any other key, the channel
LED will go o, and the channel management mode will be exited.
Aer the parameters of the working channel are modied, they will be saved into the parameter
storage automacally aer 10 seconds, and users do not need to save it manually.
Gas check key
This area contains components such as gas check key and gas ow LED. When the gas-check
key is pressed once, the gas will ow. When the key is pressed again gas ow will cease. The
gas ow LED will be on when the gas key is pressed.
Note: Users can stop gas ow by pushing the torch trigger in the gas-check state.
Control panel operaon
Aer the machine is powered on, the system will be under the funconal state that was used last me
the machine was powered o. If users want to connue the original welding task, there is no need to
make any adjustments , just connue welding as before. However, if users want to change the welding
task or welding instrucon, they should make any changes using the control panel. The recommended
operaon steps for the control panel are as below.
Select the welding mode
Select the desired welding mode by pressing the selecng key in the welding mode selecng zone if
necessary.
Select the base metal type
Select the desired base metal type by pressing the selecng key in the base metal selecng zone if
necessary.
Select the gas type