2)If the "Welding Mode" is MIG, set the MIG post-flow
time, with range of 0-5.0, accuracy of 0.5, and unit of
seconds.
2) If the "Welding Mode" is Lift TIG, set the Lift TIG
post-flow time, with range of 0-10.0, accuracy of 0.5,
and unit of seconds.
Set the Lift TIG downslope time, with range of 0-5,
accuracy of 0.5, and unit of second.
Set the MIG burn back voltage, with range of
10.0-20.0, accuracy of 0.1, and unit of voltage.
Set the MMA hot start current, with range of 0-60,
accuracy of 1, and unit of ampere.
Set the slow wire feed speed of MIG; can be set to "0",
"1", "2" or "3".
1) "0" indicates that the slow wire feed function is
disabled.
2) "1" and "2" indicate that the slow wire feed speed is
1/3 or 1/2 of the current set speed, respectively.
3) "3" indicates that the current slow wire feed speed is
3m/min.
Can be set to "0" or "1" to use wired or wireless remote
controller.
1) "0" indicates wireless remote controller.
2) "1" indicates wired remote controller.
NOTE! If entering the Welding Engineer Mode from different "Welding Mode" states,
the functional definition corresponding to the background parameters/functions may
be also different!