19
Welding current
Pulse MIG/MAG only has synergic” mode, while “separate” mode is unavailable. Under “synergic”, voltage can
be adjusted with a focus on synergic voltage±9.9V.
2Parameters setting
Under standard MIG/MAG, adjustable parameters include: pre-flow time; welding specification of initial segment:
welding current (or wire feed speed/board thickness), welding voltage, arc force (inductance); transition time from initial
to process; welding specification of process: welding current (or wire feed speed/board thickness), welding voltage, arc
force (inductance); transition time from process to crater; welding specification of crater segment: welding current (or
wire feed speed/board thickness), welding voltage, arc force (inductance); post-flow time.
Arc force: arc force range is -10~+10; 0 is the standard central value; adjust to the positive direction and arc will be
harder and weld bead will be narrower; if adjust to the negative direction, arc will be softer and weld bead will be
broadened; arc force can be set respectively at welding process, initial and crater.
Fig 5.3
Model
Welding
current
Welding
voltage
Transition
time
Pre-flow
time
Post-flow
time
Arc force
(inductance)
MIG500P
30~500A
10~50V
0.1~3.0s
0~3.0s
0~10.0s
-10~10
MIG350P
30~350A
10~42V
0.1~3.0s
0~3.0s
0~10.0s
-10~10
Note: Different welding wire has different welding current range; with different welding wire, wire feed
speed differs even under the same current
3Operation modes
Table 5-3 Pulse MIG operation modes
Modes
Sketch map
2T
Time Wire feed speed/board thickness
Arc force (inductance)
Initial segment Transition time
Welding voltage
Pre-flow time Process Crater Post-flow time