NOTE: Should icing-up occur, it is necessary to let the cooling (evaporator) coil defrost
before normal cooling operation is resumed. During this time, operate the unit in
the “HIGH FAN” position with the system at maximum air flow. When
increased or full air flow is observed, the cooling coil should be clear of ice.
SHORT CYCLING
When an air conditioner is in operation , its compressor circulates refrigerant under high pressure.
Once off, it will take two to three minutes for this high pressure to equalize.
The air conditioning compressor is unable to start against high pressure. Therefore, once the air
conditioner is turned off, it is important to leave it off for two or three minutes before restarting.
Short cycling the compressor (or starting it before pressures have equalized), will in some instances,
kick the circuit breaker or overload.
FOR AIR CIRCULATION ONLY
1. Turn the selector switch for “LOW FAN” or for maximum air flow, to “HIGH FAN”.
2. Position the louvers to the desired direction the discharge air is to flow.
NOTE: When the selector switch is in the “LOW FAN” or “HIGH FAN” position, the blower motor
will operate continuously.