8 - 8
Section C
Electrics
9803/6400
Section C
8 - 8
Issue 2*
Self Test
Self Test Function (continued)
When the desired AUTOMATIC IDLE TIME is reached, press
and hold the RESET switch for 20 seconds to enter the
setting into the controller. A buzzer will sound when the
setting is complete.
Turn the starter switch to OFF to silence the buzzer.
Other functions
Other functions, not applicable in normal use, can be
displayed using the SELECT button:
CH:1 = Min engine RPM for scrap magnet use.
CH:7 = Changing Proportional Solenoid mA Value.
If kerosene fuel is to be used it is necessary to reduce
the current at the proportional solenoid on the hydraulic
pump as follows:
1. Switch ignition on.
2. Press CHANGE button once.
3. Press PATTERN button once.
4. Press SELECT button repeatedly until monitor reads
CH:7
5. Press H MODE switch to change mA value.
(0=normal,1= reduced current).
6. Press RESET button for 20 sec until buzzer sounds.
7. Switch ignition off.
The proportional solenoid mA value is now reduced.
CH:8 = Battery level sensor.