10 - 4
Schematics, Technical Data
JS200, JS240 Hydraulic Pump P-Q Line Diagram
This diagram shows the values for the new machine.
Changes occur depending on the conditions of use.
Magnetic proportional value electric current
JS200 - 305mA
JS240 - 330mA
Engine revolutions
JS200 - 1,920r.p.m
JS240 - 2,050r.p.m
Section E
Hydraulics
9803/6400
Section E
10 - 4
Issue 1
Hydraulic Pump JS200, JS240
JS240
Measured Pressure Flow (l/min)
bar lb/in
2
kgf/cm
2
77.3 1137 80 195 - 200
145.1 2133 150 159 - 174
203.1 2986 210 112 - 123
JS200
Measured Pressure Flow (l/min)
bar lb/in
2
kgf/cm
2
77.3 1137 80 185 - 190
145.1 2133 150 126 - 143
203.1 2986 210 86 - 97
JS240
JS200