EasyManua.ls Logo

JDS Uniphase HST-3000 - Page 13

JDS Uniphase HST-3000
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 13 of 24
7. Configure Test Press the Configure Navigation key to configure test setting. Using the
Right Arrow key or Settings soft key, scroll through Settings menus
and configure your test as follows. Leave all other values at default,
unless specified in the Work Order.
For Layer 2 Testing:
For Layer 3 IP Testing:
8. View Results Press the Home key to display Summary Results.
9. Turn Laser On For optical testing, press the Action soft key and select Laser On.
10. Restart Press the Restart soft key to reset test results.
11. Check AutoNeg Stats For Electric (Copper/RJ-45) connections, if Auto Negotiation was
enabled in the Link Initiation Setup, press the Right Arrow key until
Auto-Neg Results are displayed. Verify that Link Config ACK = Yes
and Duplex = Full.
Menu
Option
Value
Comment
Test Mode
Test
Layer 2 Traffic
.
RFC 2544 Mode
Disable
SAM Complete
Disable
Link Init
Auto Negotiation
See Work Order
Set to same values as
Ethernet switch port.
Speed
See Work Order
Duplex
Full
Menu
Option
Value
Comment
Test Mode
Test
Layer 3 IP Traffic
.
RFC 2544 Mode
Disable
Link Init
Auto Negotiation
See Work Order
Set to same values as
Ethernet switch port.
Speed
See Work Order
Duplex
Full
IP Init
ARP Mode
Enable
Destination IP See Work Order
If unknown, set to IP address
of Default Gateway
Source Type
Static IP
Source IP
See Work Order
Subnet Mask
See Work Order
Default Gateway
See Work Order
Technical Support tac@jdsu.com 855-275-5378