DC Pump
OWNER’S MANUAL
DCW-2000,DCW-3000,DCW-4000,DCW-5000,DCW-6500,DCW-8000,
DCW-10000
Introduction
The DC pumps are carefully inspected and tested to ensure both safety and operating
performance. However, failure to follow the instructions and warnings in this manual
may result in pump’s damage and/or serious injury. Be sure to read and save this
manual for future reference.
● SINE wave technology ,ultra quiet operation.
● High performance with innovational motor, and energy saving up to 65%, super
● Suitable for both marine and fresh water, Rust free
● IC electronic detection ,automatic power-off protection upon no water.
● Motor protection if rotor is blocked; No copper element.
● With anti-resistant ceramic shaft, longer operation life.
● With 10 mode, adjustable the flow rate and head max.
● “Feed” Model, pause, timing, delay, restart function
● Memory function, ensure that the pump rework upon keeping the same parameter
Operating instructions
1. The pump must be connected with the controller and the 24V adaptor correctly
before work. According to the need to choose different plug and supply cord .
2. Turn on the power, press "-" and "+" button, to adjust the pump flow rate and
Head Max. and the LED instruction light will be on the relative mode
3. Lock / unlock function: press the "+" or "-" button for three seconds until the LED
light flash for two times, the controller locked; Similarly, press the "+" or "-" button for
three seconds again, LED indicator light flashes for two times, the controller unlocked
4. "FEED" function: when the pump is working, press "FEED" button, pump stops
working, the "10min" indicator lights up, the pump reworks automatically at previous
level after 10 minutes. Or you can press the “FEED” button to make the pump rework.
The LED flashing status instruction
The controller
working status
Elimination of
abnormal
phenomena
Over voltage or
under voltage
Check the input
supplying voltage
Check whether the
controller exposed
to the sunshine or
in high temperature
environment
The impeller stops
running
Check whether
something in the
pump or the parts
are wrongly
connected
Abnormal current of
the controller
Check if the pump
short of voltage or
the controller
broken
Press the "+" or "-" button for
three seconds until LED
indicator flashing for two
times, then the controller will
turn to be locked or unlocked
The key may be
broken if the light
don’t flash
Performance Parameters Table