M
Ingenieurbüro CAT, M. Zipperer GmbH +49-7634-5056-800
Wettelbrunner Straße 6 sales@jetcat.de
56 79282 Ballrechten-Dottingen www.jetcat.de
GERMANY
Instruction
m
-
PRO engines
,
1.7
-
V12.01V
The LIMITs Menu
The LIMITs menu allows the operator to adjust the following parameters of the engine, within the allowable values,
according to the performance requirements of a particular model.
Value Explanation
Minimum RPM Turbine idle speed (If IdleRPM-SET or Idle&Ramp-Set is enabled by Barom.Auto Tune it
will further appear (Auto) in the display and
the RPM is set by ECU)
Maximum RPM
F
Turbine maximum speed
Indicate the thrust at full throttle. By varying the RPM this value calls the related thrust
of the
engine
.
This provides
a save and easy way to
limit the maximum thrust.
Lowidle RPM Reduced idle speed. This function is activated if the throttle stick is in idle and the
throttle trim is set to half. The Idle speed will be decreased to the programmed value.
The acceleration time to get back to the common idle speed can take 2-5 seconds
according
the
used
engine
type.
Ignition-Mode Version of ignition type:
Kerosene-N JetCat kerosene start.
This parameter is for informational purposes only and can’t be changed
Battery Type Kind of connected Battery:
NiCd
LiPo 2Cell/7.4V
LiPo3Cell/11.1V (recommend by JetCat for PRO engines!!!)
LiFePo 3Cell/9,9V
Pb
(12V lead battery)
Barom.Auto Tune Enables the ECU to align the control system according the barometric pressure. The
possible settings are:
Disabled: No auto tuning by ECU
IdleRPM-Set: Optimize of idle RPM only
Ramp-Set: Optimize of acceleration only
Idle&Ramp-Set: IdleRPM and acceleration are optimized
Smoker Flow Only available when a bus-smoke pump is connected.
The smoke flow can be adjusted in a range of 0-100%.
Additional is shown the quantity of flow in milliliters (ml).
Fueltank size Actual capacity of the fuel tank in ml
LowFuel Limit Fuel level (ml) to activate the fuel warning function.
Telemetry Select type of telemetry protocol, only applicable in conjunction with PRO-Interface
Options are (see also instruction manual of “JetCat telemetry adapter”):
NOT USED
Futaba SBUS-2
Graupner HOTT
MPX M-Link1
Jeti
MPX M-Link2