EasyManua.ls Logo

JFL Alarmes SMARTCLOUD 18 - Enabling and Disabling Divided Mode; Enabling and Disabling Triggering Modes

JFL Alarmes SMARTCLOUD 18
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.jfl.com.br
which device has a problem, connect the programmer software to the central unit and
visualize on the monitor screen, or access through the application with the use of the ME-04
Ethernet module. To disarm the central unit, press and release a programmed button of the
remote control; with this, the armado LED turns off, and the siren issues 1 beep indicating
the disarming. In case the central unit detects the occurrence of a trigger in some zone, the
siren issues 2 more short beeps signaling the violated zone.
Through the on inlet: Apply a pulse without retention on the push button interconnected
between the on and - terminals (item 18).
Via application: Check item "access via application to the central unit" (item 21).
Obs.: * - The siren only issues an arming and disarming signaling if it is programmed (see
item 10).
- The bus siren does not signal arming and disarming.
5 ENABLE AND DISABLE THE DIVIDED MODE
The Divided Mode, when enabled, allows the user to arm and disarm the zones of the central
unit separately according to the zone programming. Zones programmed as being of area 1
are controlled by button 1 of the remote control, while those as area 2 are controlled by
button 2. Button 3 arms/disarms all zones. With the central unit disarmed, press and release
the programar button and then press and hold button 1 of the remote control for 4 seconds.
The siren issues 2 short beeps when it enables the divided mode, or 1 short beep when it
disabled it.
Obs.: - Button 1 of the remote control must be programmed.
- Zone 1 is controlled by button 1 and zone 2 is controlled by button 2.
6 ENABLE AND DISABLE THE CONTINUOUS OR
INTERRUPTED TRIGGERING
Continuous mode triggering: The central unit triggers the siren when a zone remains open.
Interrupted mode triggering: The central unit triggers the siren only once, while the zone
remains open. When the zone is restored, the central resumes normal operation.
With the central unit disarmed, press and release the programar button, then press and hold
button 2 of the remote control for 4 seconds. The siren issues 2 short beeps when it enables
the interrupted triggering, or 1 short beep when it enables the continuous triggering.
Obs.: - Button 2 of the remote control must be programmed.
- This function is only valid for wired zones (zone 1 and zone 2).
6