Operation steps: When the equipment is fed with air source, put the Run/Retract switch to operation position,
then the booster pump begins to work normally. If short-period stop of booster pump is desirable, put the
Run/Retract switch to the reset position. For long-period shut down, first turn the Run/Retract switch to the
reset position, then pull the lock bolt to release material (pressure release) while keeping the booster pump
working. When the booster pump shaft runs to the designed protection location, the pump will stop working.
Then, release the bolt and switch off the main machine air source.
Using the Run/Retract switch, you can control the working or stopping of the booster pump. In addition, when
the equipment is stopped, the reset switch makes it possible to put the piston in the anti-solidification liquid
cylinder at the black material side of the booster pump to its extreme imbibition position. The lubricant fills
the lubricant cylinder with the working portion of the black material shaft and of the lubricant cylinder in full
contact with the lubricant, segregated from the air. This prevents the generation of black material crystals,
which may scratch sealing parts.
4.6 Emergency stop button
When stopping is desired in electrical equipment emergencies, just push the emergency stop button
(Figure7). Then, all the electrical components of the equipment stop; turn the knob clockwise, the knob will
reset automatically. The electrical system of the equipment resumes the work condition.
Note: Emergency stop button controls only the electrical system in the equipment. When this button is
pushed, the booster pump of the main machine may still keep running. If you want to stop this pump, turn
the Run/Retract switch to the reset position or switch off the main machine air source.
4.7 Self-lock start-up button for heater:
When the main power switch (Figure 8) on the electrical cabinet on the back of the main machine is closed,
if it is desired to heat the black material (component A) and the white material (component B), then push the
main temperature controller for heating on the control panel to a lower position to switch on the power. The
control circuit of the temperature controller is powered on and the heating system works accordingly to the
preset temperature. When the main temperature controller is in a high position, the power is switched off.
So, if you do not want to use the heating system, just put the main temperature controller into its high position.