EasyManua.ls Logo

JMB VL-3E-1 Evolution - Smoke and Fire Response

JMB VL-3E-1 Evolution
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VL-3E-1 Pilot Operating Handbook
date of issue:
16/39
3.3 Smoke and fire
3.3.1 Fire on ground
1. Fuel valve - off
2. Throttle - close
3. Master switch - off
4. Ignition - off
5. Abandon the aeroplane
6. Extinguish fire if possible or call fire department.
3.3.2 Fire during take-off
1. Fuel valve - off
2. Throttle - full
3. Speed - 120 km/h (65 kts)
4. Master switch - off
5. Ignition - off
6. Land and brake
7. Abandon the aeroplane
8. Extinguish fire if possible or call fire department.
3.3.3 Fire in flight
1. Fuel valve - off
2. Throttle - full
3. Ignition - off after using up fuel in carburetors and engine stopping
4. Master switch - off
5. Choose of area - heading to the nearest airport or choose emergency landing area
6. Emerg. landing - perform according to par.3.6.1
7. Abandon the aeroplane
8. Extinguish fire if possible or call fire department.
3.4 Glide
Gliding may be used in case of engine failure.
1. Speed - ~ 100 km/h (55 kts)
2. Flaps - retracted
3. Instruments - within permitted limits

Table of Contents