4.15.6 Reset Procedures
The Reset Procedures function is used to delete the capture memory or to
reset a number of settings to the factory settings.
1. Press the MENU piston.
2. Use the - and + pistons to select the Reset Procedures function on
the display.
3. Press the SET piston. The display shows the menu for the Reset
Procedures.
4. Use the - and + pistons to select the desired procedure.
Memory: Clears the entire capture memory.
MIDI: Resets the factory settings of the MIDI stops.
Preset: Resets the factory settings of the fixed combinations.
Crescendo: Resets the factory settings of the General
Crescendo pedal.
Reverb ASR-12: Resets the factory settings of the reverb.
This is subdivided into: Length and Program.
5. Press the SET piston. The display requests confirmation.
6. Use the - and + pistons to select No or Yes.
7. Press the SET piston for confirmation.
8. Press the MENU piston to return to the main menu.
9. Press the MENU piston again to exit the Easy Menu.
4.15.7 Datadump
The Datadump Mode function sends settings from the organ to a storage
medium (for example a sequencer) through the MIDI SEQ. output. See §
3.4.
1. Press the MENU piston.
2. Use the - and + pistons to select the Datadump on the display.
3. Press the SET piston. The Press Set piston text appears on the
display.
4. Make sure the desired storage medium is properly connected.
5. Press the SET piston again. When data is being sent, Sending data
appears on the display.
Do not use the organ when the Sending Data text is on the
display.
6. Press the MENU piston to return to the main menu.
7. Press the MENU piston again to exit the Easy Menu.