SECURITY AND ARMING
Setting
Default
Description
Secure Arming
Disabled
Require user code for arming the panel. NOTE: this option shall be enabled for UL/cUL.
Refuse Arming When Battery
Low
Disabled
Will not allow panel to arm if battery is low (below 8%)
Auto Bypass
Enabled
Toggle whether or not to bypass open or tampered sensors automatically. NOTE: Shall be disabled
for UL/cUL. This setting is turned off and greyed out when the “En Grade 2” setting is enabled.
Final Exit Door Arming
Disabled
When enabled, if Arm Away is selected at the panel then there is no timed exit delay. Instead,
the system is not fully armed until an Entry/Exit door is violated. NOTE: This setting is greyed out an
unavailable unless EN Grade 2 is enabled.
Auto Stay
Enabled
If panel is armed “Away” but a delay door is not opened, the panel assumes you are still home
and changes arming to “Stay” mode
Arm Stay - No Delay
Enabled
Arm stay immediately with no countdown timer
Auto Exit Time Extension
Enabled
Automatically extend countdown timer if delay door is opened during countdown process a
second time
Keyfob Instant Arming
Enabled
When enabled, turns off exit delay if keyfob is used to arm the system
Keyfob Alarm Disarm
Disabled
When enabled this will Allow a keyfob to disarm alarm events, except panics originating from
the same key fob