When Disabled, a Keyfob will not be able to disarm the panel
If a confirmed alarm occurs on a burglary zone, the system is locked out after disarming until a 5
digit reset code provided by the installer is entered in.
Allow Master Code to Access
Security and Arming
Allow the master code to access these features and settings.
NOTE: this option shall be disabled for UL/cUL. This option shall be enabled for UL Commercial Burg installations.
How much time users have to enter their code after opening a door (30-240secs). With SIA
limits disabled the minimum time can be set to 5 secs.
NOTE: For UL Commercial Burg (UL2610) maximum entry delay should not exceed 60s
How much time users have to exit the location before the panel arms itself (30-254secs). With
SIA limits disabled the minimum time can be set to 5 secs. Door/Window group 10 follows the
“Normal Exit Delay” NOTE: For UL Commercial Burg (UL2610) maximum exit delay should not exceed 60s
A second separate entry delay that can be used on a sensor needing more time when tripped
(45-240secs). With SIA limits disabled the minimum time can be set to 5 secs
A second separate exit delay that can be used on a sensor needing more time when tripped
(45-254secs). With SIA limits disabled the minimum time can be set to 5 secs. Door/Window
group 12 follows the “Long Exit Delay”