INSTALLING THE PANEL
WIRING DIAGRAM
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 11 198
IMPORTANT:
- 7v⎓DC Transformer: Use 18AWG
(0.75mm
2
) wire no longer than 98.5ft
(30m) to ensure sufficient power is
received at the panel.
* The minimum permissible wire size shall
not be smaller than 22 AWG (0.33mm
2
)
** 7v⎓DC power supply output shall not
exceed 15VA (15W) under any conditions
NOTES
**WARNING! Use 7v⎓DC**
Power Supply ONLY
7v⎓DC* IN
BARREL JACK
BARREL JACK FOR USE
WITH SUPPLIED
BARREL CONNECTOR
CABLE ONLY. STRIPED
WIRE IS POSITIVE (+)
Input rating: 100-240vAC, 50/60Hz, 0.68A
Output rating: 7.0vDC, 1.0A or 7.0vDC, 1.5A
Model SW-070100AB or SW-070150A
For EN Grade 2 installations use only model
SW61-070150-03 Output rated: 7VDC/1.5A