SECURITY AND ARMING
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 45 198
PROGRAMMING
Setting
Default
Description
Long Entry Delay
100 Secs
A second separate entry delay that can be used on a sensor needing more time when tripped
(45-240secs). With SIA limits disabled the minimum time can be set to 5 secs. NOTE: Not for use with
EN Grade 2
Long Exit Delay
120 Secs
A second separate exit delay that can be used on a sensor needing more time when tripped
(45-254secs). With SIA limits disabled the minimum time can be set to 5 secs. Door/Window
group 12 follows the “Long Exit Delay. NOTE: Not for use with EN Grade 2