Please note: When using the PGx905 with Group 51, the High & Low threshold settings are set to 40°F and 100°F (4°C
and 38°C) by default. When using Group 52, the Low threshold setting is set to 40°F (4°C) by default. When using
Group 53, the High threshold setting is set to 100°F (38°C) by default. Thresholds can be customized between -22°F
and 158°F (-40°C and 85°C).
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF 76 198
TEMPERATURE
GROUP
NAME
SUPERVISED
SCENARIO
51
Temp Non Reporting
Y
Only for use with the PowerG Temp Sensor (PGx905). This sensor
group does not report to the Central Station. Allows for actual
temperature monitoring (thermometer) with customizable high/
low threshold settings
52
Freeze
Y
Triggers an alarm when sensor detects low temperatures.
NOTE: temperature sensor functionality has not been evaluated by UL/cUL
53
Temp Reporting
Y
Triggers an alarm when sensor detects high temperatures.
NOTE: temperature sensor functionality has not been evaluated by UL/cUL
SENSOR GROUPS