6112628-UIM-B-0622
Johnson Controls Ducted Systems 15
Table 10: Electrical data for multi-source power supply: 208/230-1-60
Air
handlers
models
Heater
models
1
Heater
amps (A)
at 240 V
Minimum circuit ampacity (A)
MOP
2
(A)
208 V 230 V 208 V 230 V
Circuit Circuit
First
3
Second Third
First
3
Second Third
First
3
Second Third
First
3
Second Third
B24C 8HK16501506 60 24.7 43.5 — 26.9 48.1 — 25 45 — 30 50 —
B30D
8HK16501506 60 26.2 43.5 — 28.4 48.1 — 30 45 — 30 50 —
8HK16502006 80 48.0 43.3 — 52.6 47.8 — 50 45 — 60 50 —
B36D
8HK16501506 60 26.2 43.5 — 28.4 48.1 — 30 45 — 30 50 —
8HK16502006 80 48.0 43.3 — 52.6 47.8 — 50 45 — 60 50 —
C36D
8HK16501506 60 26.2 43.5 — 28.4 48.1 — 30 45 — 30 50 —
8HK16502006 80 48.0 43.3 — 52.6 47.8 — 50 45 — 60 50 —
C42F
8HK16501506 60 26.2 43.5 — 28.4 48.1 — 30 45 — 30 50 —
8HK16502006 80 48.0 43.3 — 52.6 47.8 — 50 45 — 60 50 —
C48G
8HK16501506 60 28.2 43.5 — 30.4 48.1 — 30 45 — 35 50 —
8HK16502006 80 50.0 43.3 — 54.6 47.8 — 50 45 — 60 50 —
D48G
8HK16501506 60 28.2 43.5 — 30.4 48.1 — 30 45 — 35 50 —
8HK16502006 80 50.0 43.3 — 54.6 47.8 — 50 45 — 60 50 —
C60H
8HK16501506 60 28.2 43.5 — 30.4 48.1 — 30 45 — 35 50 —
8HK16502006 80 50.0 43.3 — 54.6 47.8 — 50 45 — 60 50 —
D60H
8HK16501506 60 28.2 43.5 — 30.4 48.1 — 30 45 — 35 50 —
8HK16502006 80 50.0 43.3 — 54.6 47.8 — 50 45 — 60 50 —
8HK16502506 100 50.0 43.3 21.6 54.6 47.8 23.9 50 45 25 60 50 25
D60J
8HK16501506 60 28.2 43.5 — 30.4 48.1 — 30 45 — 35 50 —
8HK16502006 80 50.0 43.3 — 54.6 47.8 — 50 45 — 60 50 —
8HK16502506 100 50.0 43.3 21.6 54.6 47.8 23.9 50 45 25 60 50 25
1. 8HK1 = with service disconnect, no breaker jumper bar
2. MOP = Maximum Overcurrent Protection device; must be HACR type circuit breaker or time delay fuse. The first circuit includes blower motor amps. Refer to the lat-
est edition of the National Electric Code or in Canada the Canadian electrical Code and local codes to determine correct wire sizing.
Table 11: Electrical data for single source power supply: 208/230-3-60
Air handler models
Heater models
1
Heater
amps (A)
at 240 V
Field wiring
Minimum circuit ampacity (A)
MOP
2
(A)
208 V 230 V 208 V 230 V
B18B 8HK06501025 23.1 28.2 30.9 30 35
B24C
8HK06501025 23.1 28.2 30.9 30 35
8HK06501525 34.6 40.7 44.7 45 45
B30D
8HK06501025 23.1 29.7 32.4 30 35
8HK06501525 34.6 42.2 46.2 45 50
8HK16502025
1
46.2 54.7 60.0 60 60
B36D
8HK06501025 23.1 29.7 32.4 30 35
8HK06501525 34.6 42.2 46.2 45 50
8HK16502025
1
46.2 54.7 60.0 60 60
C36D
8HK06501025 23.1 29.7 32.4 30 35
8HK06501525 34.6 42.2 46.2 45 50
8HK16502025
1
46.2 54.7 60.0 60 60
C42F
8HK06501025 23.1 29.7 32.4 30 35
8HK06501525 34.6 42.2 46.2 45 50
8HK16502025
1
46.2 54.7 60.0 60 60
C48G
8HK06501025 23.1 31.7 34.4 35 35
8HK06501525 34.6 44.2 48.2 45 50
8HK16502025
1
46.2 56.7 62.0 60 70
D48G
8HK06501025 23.1 31.7 34.4 35 35
8HK06501525 34.6 44.2 48.2 45 50
8HK16502025
1
46.2 56.7 62.0 60 70
Continued on next page