Table listing nominal capacities and sound pressure levels for various YAES-SA/DSA models.
Details on twin helical semi-hermetic screw compressors, including their components and operation.
Description of available star/delta open and closed transition motor starting options.
Explanation of the dedicated air-cooled heat exchanger for oil cooling.
Details on the construction and components of each independent refrigerant circuit.
Description of the Shell and Tube type Direct Expansion Evaporator.
Details on condenser coil construction, fans, and motors.
Information on the factory-wired control and motor starting equipment panels.
Overview of microprocessor functions, displays, and standard controls.
Details on high and low motor current protection provided by the microprocessor.
Description of available power and control options for the units.
Factory-fitted desuperheaters to provide hot water during cooling operation.
Use of electronic expansion valves for improved efficiency.
Double thickness insulation for enhanced efficiency and low temperature applications.
Options for evaporator connections on the right-hand or left-hand side.
Standard condenser coils use un-coated aluminium fin stock.
Optional condenser coils with gold coloured epoxy coating.
Condenser coils with corrosion-resistant copper fins for added protection.
Heavy gauge welded wire mesh guards for exterior condenser coil faces.
Infill panels made from powder-painted galvanised steel for aesthetic finishing.
Kit to provide shade or air gap around panels at ambients above 45°C.
Fans and motors suitable for high external static conditions.
Level adjustable spring and cage type isolators for unit base rails.
Information needed to select a YORK YAES chiller for cooling applications.
Step-by-step guide for selecting the appropriate chiller model.
Information needed to select a YORK YAES glycol chiller.
Step-by-step guide for selecting a chiller for glycol cooling.
Details on refrigerant circuit quantity, type, and oil charge.
Information on compressor type, capacity control, and number.
Physical data for the evaporator, including water volume and coil face area.
Data on condenser coil face area, tube rows, and fan configuration.
Specifications for fan nominal speed, air flow, and pressure.
Length, width, and height of the unit.
Shipping and operating weights, including variations.
Additional weight for low sound units and aesthetic panels.
Details on refrigerant circuit quantity, type, and oil charge for DSA models.
Compressor specifications including type and capacity control.
Physical data for the evaporator in DSA models.
Specifications for the air-cooled condenser in DSA models.
Fan data including speed, air flow, and pressure for DSA models.
Physical dimensions for YAES-DSA models.
Shipping and operating weights for YAES-DSA units.
Additional weight for low sound and aesthetic panel options on DSA units.
Diagrams for standard and multi-point power supply connections.
Diagram illustrating customer wiring connections for all models.
Diagrams showing required clearances for all unit models.
Dimensional drawings for YAES0405SA and YAES0475SA models.
Dimensional drawings for YAES0545SA, YAES0575SA and YAES0645SA models.
Dimensional drawings for YAES0685SA, YAESSA0715 and YAESSA0785 models.
Dimensional drawings for YAES0905SA and YAES0985SA models.
Dimensional drawings for the YAES1075SA model.
Dimensional drawings for YAES1245SA and YAES1405SA models.
Dimensional drawings for YAES1505DSA, YAES1575DSA and YAES1645DSA models.
Dimensional drawings for the YAES1715DSA model.
Dimensional drawings for the YAES1785DSA model.
Dimensional drawings for YAES1855DSA and YAES1925DSA models.
General overview of YORK YAES chillers and manual purpose.
Information on YORK International's warranty terms and conditions.
Essential health and safety requirements and EU directives conformity.
Outline of responsibilities for safe operation and maintenance.
Explanation of symbols used and manual content.
Guidelines on suitability for application and avoiding misuse.
Instructions for operating the emergency stop device.
Description of safety labels affixed to the unit.
Safety data for refrigerant (R134a) and oil, including handling precautions.
Overview of YAES-SA and YAES-DSA single packaged air cooled chillers.
Details on twin helical semi-hermetic screw compressors.
Explanation of compressor capacity control mechanisms.
Description of the oil cooling system.
Details on refrigerant piping and liquid line components.
Information on condenser coil construction and fans.
Details on the Shell and Tube Direct Expansion Evaporator.
Description of power and control panel enclosures and contents.
Functions and displays of the microprocessor control system.
Details on motor current protection features.
Description of available accessories and options.
Explanation of the unit model number nomenclature.
Overview of the unit's cooling cycle and operation.
Precautions for transporting, storing, and handling the unit.
Procedure for inspecting the unit upon delivery for transit damage.
Instructions and precautions for safely moving the unit.
Instructions for using lifting lugs and shackles.
Detailed instructions on using shackles for lifting the unit.
Reference to Section 9 for details on lifting weights and distribution.
Essential site requirements for optimal unit performance and service access.
Required clearances around the unit for airflow and maintenance.
Instructions for installing optional vibration isolators.
General recommendations for satisfactory pipework operation.
Guidelines on water quality and treatment to maintain performance.
Suggested pipework arrangements for single and multiple unit installations.
Details on standard chilled liquid connection types and sizes.
Recommendations for refrigerant relief valve piping to prevent injury.
General recommendations for satisfactory ductwork installation.
Recommendations for safe and satisfactory electrical connections.
Guidelines for power wiring specifications and connections.
Description of voltage-free contact terminal block wiring and output signals.
Details on system inputs, flow switch, and remote controls.
Diagram illustrating the typical layout of components within the control panel.
Diagrams for main and auxiliary panel power supply connections.
Wiring diagram for customer connections to main and auxiliary panels.
Pre-commissioning checks to be made with the customer supply switched off.
Step-by-step procedure for the initial start-up and checks.
Overview of unit operation and control functions.
Procedure for starting the unit and initial checks.
Description of automatic operation, load adjustment, and fan control.
Procedure for stopping the unit and precautions for low ambient temperatures.
Guidelines for continuous operation and routine maintenance.
Daily checks to be performed by the operator/customer.
Details of minor and major maintenance services to be performed by qualified engineers.
Recommendations for periodic in-service inspection of vessel thickness.
Guide to identifying and resolving common operational problems.
Calibration data for temperature and pressure sensors.
Graphs illustrating evaporator pressure drops based on flow rate.
Table detailing operating limitations for YAES-SA and YAES-DSA models.
Detailed physical specifications for YAES-SA and YAES-DSA units.
Sound power level data in decibels for standard and low sound models.
Electrical data including nominal, maximum, and start-up amps.
Electrical data for standard, low sound, and high pressure fans.
Data on single point and multi-point power connections and protective devices.
Dimensional drawings for various YAES-SA and YAES-DSA models.
Diagrams showing component locations for 2, 3, and 4 system models.
Point load and AVM data, including isolator details.
Recommended clearances and dimensions for unit installation.
Information on obtaining unit spare parts from YORK.
Guidance on using the correct type of compressor oil.
List of associated wiring diagrams, connections, and legend/notes.
Procedures for safely decommissioning and disposing of the unit and its components.
Table listing nominal capacities and sound pressure levels for various YAES-SA/DSA models.
Details on twin helical semi-hermetic screw compressors, including their components and operation.
Description of available star/delta open and closed transition motor starting options.
Explanation of the dedicated air-cooled heat exchanger for oil cooling.
Details on the construction and components of each independent refrigerant circuit.
Description of the Shell and Tube type Direct Expansion Evaporator.
Details on condenser coil construction, fans, and motors.
Information on the factory-wired control and motor starting equipment panels.
Overview of microprocessor functions, displays, and standard controls.
Details on high and low motor current protection provided by the microprocessor.
Description of available power and control options for the units.
Factory-fitted desuperheaters to provide hot water during cooling operation.
Use of electronic expansion valves for improved efficiency.
Double thickness insulation for enhanced efficiency and low temperature applications.
Options for evaporator connections on the right-hand or left-hand side.
Standard condenser coils use un-coated aluminium fin stock.
Optional condenser coils with gold coloured epoxy coating.
Condenser coils with corrosion-resistant copper fins for added protection.
Heavy gauge welded wire mesh guards for exterior condenser coil faces.
Infill panels made from powder-painted galvanised steel for aesthetic finishing.
Kit to provide shade or air gap around panels at ambients above 45°C.
Fans and motors suitable for high external static conditions.
Level adjustable spring and cage type isolators for unit base rails.
Information needed to select a YORK YAES chiller for cooling applications.
Step-by-step guide for selecting the appropriate chiller model.
Information needed to select a YORK YAES glycol chiller.
Step-by-step guide for selecting a chiller for glycol cooling.
Details on refrigerant circuit quantity, type, and oil charge.
Information on compressor type, capacity control, and number.
Physical data for the evaporator, including water volume and coil face area.
Data on condenser coil face area, tube rows, and fan configuration.
Specifications for fan nominal speed, air flow, and pressure.
Length, width, and height of the unit.
Shipping and operating weights, including variations.
Additional weight for low sound units and aesthetic panels.
Details on refrigerant circuit quantity, type, and oil charge for DSA models.
Compressor specifications including type and capacity control.
Physical data for the evaporator in DSA models.
Specifications for the air-cooled condenser in DSA models.
Fan data including speed, air flow, and pressure for DSA models.
Physical dimensions for YAES-DSA models.
Shipping and operating weights for YAES-DSA units.
Additional weight for low sound and aesthetic panel options on DSA units.
Diagrams for standard and multi-point power supply connections.
Diagram illustrating customer wiring connections for all models.
Diagrams showing required clearances for all unit models.
Dimensional drawings for YAES0405SA and YAES0475SA models.
Dimensional drawings for YAES0545SA, YAES0575SA and YAES0645SA models.
Dimensional drawings for YAES0685SA, YAESSA0715 and YAESSA0785 models.
Dimensional drawings for YAES0905SA and YAES0985SA models.
Dimensional drawings for the YAES1075SA model.
Dimensional drawings for YAES1245SA and YAES1405SA models.
Dimensional drawings for YAES1505DSA, YAES1575DSA and YAES1645DSA models.
Dimensional drawings for the YAES1715DSA model.
Dimensional drawings for the YAES1785DSA model.
Dimensional drawings for YAES1855DSA and YAES1925DSA models.
General overview of YORK YAES chillers and manual purpose.
Information on YORK International's warranty terms and conditions.
Essential health and safety requirements and EU directives conformity.
Outline of responsibilities for safe operation and maintenance.
Explanation of symbols used and manual content.
Guidelines on suitability for application and avoiding misuse.
Instructions for operating the emergency stop device.
Description of safety labels affixed to the unit.
Safety data for refrigerant (R134a) and oil, including handling precautions.
Overview of YAES-SA and YAES-DSA single packaged air cooled chillers.
Details on twin helical semi-hermetic screw compressors.
Explanation of compressor capacity control mechanisms.
Description of the oil cooling system.
Details on refrigerant piping and liquid line components.
Information on condenser coil construction and fans.
Details on the Shell and Tube Direct Expansion Evaporator.
Description of power and control panel enclosures and contents.
Functions and displays of the microprocessor control system.
Details on motor current protection features.
Description of available accessories and options.
Explanation of the unit model number nomenclature.
Overview of the unit's cooling cycle and operation.
Precautions for transporting, storing, and handling the unit.
Procedure for inspecting the unit upon delivery for transit damage.
Instructions and precautions for safely moving the unit.
Instructions for using lifting lugs and shackles.
Detailed instructions on using shackles for lifting the unit.
Reference to Section 9 for details on lifting weights and distribution.
Essential site requirements for optimal unit performance and service access.
Required clearances around the unit for airflow and maintenance.
Instructions for installing optional vibration isolators.
General recommendations for satisfactory pipework operation.
Guidelines on water quality and treatment to maintain performance.
Suggested pipework arrangements for single and multiple unit installations.
Details on standard chilled liquid connection types and sizes.
Recommendations for refrigerant relief valve piping to prevent injury.
General recommendations for satisfactory ductwork installation.
Recommendations for safe and satisfactory electrical connections.
Guidelines for power wiring specifications and connections.
Description of voltage-free contact terminal block wiring and output signals.
Details on system inputs, flow switch, and remote controls.
Diagram illustrating the typical layout of components within the control panel.
Diagrams for main and auxiliary panel power supply connections.
Wiring diagram for customer connections to main and auxiliary panels.
Pre-commissioning checks to be made with the customer supply switched off.
Step-by-step procedure for the initial start-up and checks.
Overview of unit operation and control functions.
Procedure for starting the unit and initial checks.
Description of automatic operation, load adjustment, and fan control.
Procedure for stopping the unit and precautions for low ambient temperatures.
Guidelines for continuous operation and routine maintenance.
Daily checks to be performed by the operator/customer.
Details of minor and major maintenance services to be performed by qualified engineers.
Recommendations for periodic in-service inspection of vessel thickness.
Guide to identifying and resolving common operational problems.
Calibration data for temperature and pressure sensors.
Graphs illustrating evaporator pressure drops based on flow rate.
Table detailing operating limitations for YAES-SA and YAES-DSA models.
Detailed physical specifications for YAES-SA and YAES-DSA units.
Sound power level data in decibels for standard and low sound models.
Electrical data including nominal, maximum, and start-up amps.
Electrical data for standard, low sound, and high pressure fans.
Data on single point and multi-point power connections and protective devices.
Dimensional drawings for various YAES-SA and YAES-DSA models.
Diagrams showing component locations for 2, 3, and 4 system models.
Point load and AVM data, including isolator details.
Recommended clearances and dimensions for unit installation.
Information on obtaining unit spare parts from YORK.
Guidance on using the correct type of compressor oil.
List of associated wiring diagrams, connections, and legend/notes.
Procedures for safely decommissioning and disposing of the unit and its components.