EasyManua.ls Logo

Johnson Pump TG GS2-25 - Safety; General

Johnson Pump TG GS2-25
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
A.0500.501 – IM-TGGS/05.01 EN (03/2013)
1.3 Safety
1.3.1 General
Important!
The pump must not be used for other purposes than recommended and quoted for without
consulting your local supplier.
A pump must always be installed and used in accordance with existing national and local sanitary
and safety regulations and laws.
When ATEX pump/pump unit is supplied, the separate ATEX manual must be considered
• Alwayswearsuitablesafetyclothingwhenhandlingthepump.
• Anchorthepumpproperlybeforestart-uptoavoidpersonalinjuryand/ordamagetothepump
unit.
• Installshut-offvalvesonbothsidesofthepumptobeabletoshutofftheinletandoutletbefore
service and maintenance. Check to see that the pump can be drained without injuring anyone
and without contaminating the environment or nearby equipment.
• Makesurethatallmovablepartsareproperlycoveredtoavoidpersonalinjury.
• Allelectricalinstallationworkmustbecarriedoutbyauthorizedpersonnelinaccordancewith
EN60204-1 and/or local regulations. Install a lockable circuit breaker to avoid inadvertent
starting. Protect the motor and other electrical equipment from overloads with suitable
equipment. The electric motors must be supplied with ample cooling air.
In environments where there is risk of explosion, motors classified as explosion-safe must be
used, along with special safety devices. Check with the governmental agency responsible for
such precautions.
• Improperinstallationcancausefatalinjuries.
• Dust,liquidsandgasesthatcancauseoverheating,shortcircuits,corrosiondamageandre
must be kept away from motors and other exposed equipment.
• Ifthepumphandlesliquidshazardousforpersonorenvironment,somesortofcontainermust
be installed into which leakage can be led. All (possible) leakage should be collected to avoid
contamination of the environment.
• Keeparrowsandothersignsvisibleonthepump.
• Ifthesurfacetemperatureofthesystemorpartsofthesystemexceeds60°C,theseareasmust
be marked with warning text reading ”Hot surface” to avoid burns.
• Thepumpunitmustnotbeexposedtorapidtemperaturechangesoftheliquidwithoutprior
pre-heating/pre-cooling. Big temperature changes can cause crack formation or explosion,
which in turn can entail severe personal injuries.
• Thepumpmustnotoperateabovestatedperformance.Seesection3.5Maincharacteristics.
• Beforeinterveninginthepump/system,thepowermustbeshutoffandthestartingdevicebe
locked. When intervening in the pump unit, follow the instructions for disassembly/assembly,
chapter 4.0. If the instructions are not followed, the pump or parts of the pump can be damaged.
It will also invalidate the warranty.
• Gearpumpsmayneverruncompletelydry.Dryrunningproducesheatandcancausedamageto
internal parts such as bush bearings and shaft seal. When dry running is required, the pump has
e.g. to be run a short time with liquid supply.
Note! A small quantity of liquid should remain in the pump to ensure lubrication of internal parts.
If there is a risk for dry running for a longer period, install a suitable dry running protection.
Consult your local supplier.
• Ifthepumpdoesnotfunctionsatisfactorily,contactyourlocalsupplier.

Table of Contents