Johnson S1-TTSCC01 - Air Handler Bypass Humidifier Wiring; Furnace Fan Powered Humidifier Wiring

Johnson S1-TTSCC01
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
542933-UIM-C-0112
14 Johnson Controls Unitary Products
Communicating Air Handler
Fan Powered Humidifiers
Communicating Furnace
FIGURE 13:
Air Handler Bypass
FIGURE 14: Furnace Fan Powered
B-
C
B-
R
W1
W2
O
HUM
X/L
R
G
Y/Y2
Y1
COM
Touch Screen
Communicating Control
Air Handler
Communicating Control
Air Conditioner/Heat Pump
Communicating Control
A+
C
B-
R
A+
C
B-
R
A+
HUM OUT
HOT
NEUTRAL
C
R
Bypass Humidifier
B-
C
B-
R
W1
W2
O
HUM
X/L
R
G
Y/Y2
Y1
COM
Touch Screen
Communicating Control
Air Handler
Communicating Control
Air Conditioner/Heat Pump
Communicating Control
A+
C
B-
R
A+
C
B-
R
A+
HUM OUT
HOT
NEUTRAL
Fan Powered Humidifier
120 VAC Plug
Wall outlet
Jumper