USER AND INSTALLATION MANUAL
Compact MPA
Compact MPA
Public address and
general alarm system

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the jotron PHONTECH 1671 and is the answer not in the manual?

jotron PHONTECH 1671 Specifications

General IconGeneral
Brandjotron
ModelPHONTECH 1671
CategoryMarine Equipment
LanguageEnglish

Summary

3 TECHNICAL DATA

3.1 MPA 1600 OPERATION UNIT

Provides technical specifications for the MPA 1600 Operation Unit, including voltage, current, and dimensions.

3.2 MPA 1601 PA CONTRON UNIT

Details technical specifications for the MPA 1601 PA Control Unit, including dimensions and ingress protection.

3.3 MPA 1603 GA ALARM PANEL

3.4 AMPLIFIER 1671

Provides electrical and general technical data for the Amplifier 1671.

4 PERFORMANCE

4.1 GENERAL ALARM

Describes the General Alarm tone sequence, duration, and frequency customization.

4.3 REDUNDANCY

Details measures for achieving full redundancy in the PA/GA system.

4.3.1 CENTRAL EQUIPMENT

Details the duplication and separation requirements for central equipment for full redundancy.

4.3.2 LOUDSPEAKER DISTRBUTION NETWORK

Specifies the need for duplicated and separately routed loudspeaker distribution networks.

4.3.3 ALARM PANEL

Recommends a minimum of two MPA 1603 Alarm Panels for redundancy.

4.3.4 CONTROL UNIT

Recommends a minimum of two MPA 1601 Control Units for redundancy.

4.9 POWER FAILURE

4.12 CABINET POWER TERMINAL CONNECTIONS

4.13 CABINET POWER FAILURE RELAY CONNECTIONS

5 INSTALLATION PROCEDURE

5.2 INSTALLATION GUIDE

Provides a guide for the installation process, covering planning and general aspects.

5.2.3 LOUDSPEAKER SELECTION AND SOUND PRESSURE LEVEL

5.2.7 AMPLIFIERS

5.4 FEEDBACK/INTERFERENCE CANCELLATION

5.5 POWER

6 CONFIGURATION

6.2.1 CONNECTING TO SERVICE PORT

6.2.2 SETTING A STATIC ADDRESS LOCALLY

6.2.3 IP ADDRESS AND LOGIN INFORMATION

6.3 CONFIGURATION – GENERAL

6.4 CONFIGURATION – AUDIO OUTPUT

6.5 CONFIGURATION - AUDIO INPUT

6.6 CONFIGURATION – CONTROL UNITS

6.7 CONFIGURATION – USERS

6.8 CONFIGURATION – EXTERNAL ALARM INPUTS

6.9 CONFIGURATION – SNMP/NETWORK

6.10 CONFIGURATION – ADVANCED

7 OPERATING PROCEDURE

7.3.1 EMERGENCY PAGING

Details the highest priority paging method, EM PA, and its operational aspects.

7.3.1.1 PRIORITY

Explains EM PA's priority over entertainment, normal paging, and General Alarm.

7.3.1.2 DESCRIPTION

Describes how to initiate and conduct Emergency Paging using access panels.

7.3.2 PAGING

7.3.2.1 PRIORITY

Outlines PA paging priority over entertainment and volume controls.

7.3.2.2 DESCRIPTION

Explains how to perform normal paging to pre-programmed or selected zones.

7.3.3 GENERAL ALARM

7.3.3.1 PRIORITY

Defines General Alarm's priority over other alarms, entertainment, and normal paging.

7.3.3.2 DESCRIPTION

Describes how to initiate and terminate General Alarm using the alarm panel.

8 COMMISSIONING PROCEDURE

8.4 FUNCTIONAL TESTING OF UNITS

Details functional testing procedures for the various units within the system.

8.4.2 MPA 1601/1643 TALK UNITS

8.4.2.4 PRIORITY BY NORMAL PAGING "PA"

8.4.2.5 EXTERNAL CONTROL OUTPUTS

8.4.4 MPA 1603 ALARM PANEL

8.4.7 FAILURE / WARNING OUTPUTS

8.4.8 REDUNDANCY TEST (DUPLICATED SYSTEM ONLY)

8.4.9 SOUND PRESSURE LEVEL