EasyManuals Logo

jotron PHONTECH 1671 User Manual

jotron PHONTECH 1671
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
19
User and Installaon Manual
Compact MPA
4.12 CABINET POWER TERMINAL CONNECTIONS
4.12.1 AC + DC VERSION
The primary power source for the Compact MPA Cabinet is 230VAC with 24VDC as backup.
TB1 TB2
1
230VAC
Live
1
24VDC2 2
3 3
4
230VAC
Neutral
4 24VDC (fuse)
5 5
0VDC6 6
7
PE
GND
7
8 8 0VDC (fuse)
9 9
PE
GND
TB3 10
1 MPA 24VDC backup (supplied from 1671)
2 MPA 0VDC backup (supplied from 1671)
4.12.2 AC + AC VERSION
The primary power source for the Compact MPA Cabinet is 230VAC with addional 230VAC as backup.
TB1 TB2
1
230VAC
Live
1
2230VAC
Live
2 2
3 3
4
230VAC
Neutral
4
230VAC
Neutral
5 5
6 6
7
PE
GND
7
PE
GND
8 8
9 9
TB3 10
1 MPA 24VDC backup (supplied from 1671)
2 MPA 0VDC backup (supplied from 1671)
4.13 CABINET POWER FAILURE RELAY CONNECTIONS
The power failure relays K1 and K2 are DPDT relays with one pole on 11, 12 and 14 and the other pole on 21, 22 and 24.
K1 K2
11 Primary power fail – Common contact 21 11 Secondary power fail – Common contact 21
12 Primary power fail – NC contact 22 12 Secondary power fail – NC contact 22
14 Primary power fail – NO contact 24 14 Secondary power fail – NO contact 24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jotron PHONTECH 1671 and is the answer not in the manual?

jotron PHONTECH 1671 Specifications

General IconGeneral
Brandjotron
ModelPHONTECH 1671
CategoryMarine Equipment
LanguageEnglish

Related product manuals