EasyManua.ls Logo

Joyetech eVic VTwo - Battery and Atomizer Alerts; Temperature and Overheating Alerts

Joyetech eVic VTwo
55 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
INNOCIGS EVIC VTWO – ERROR MESSAGES & PROTECTIONS
Atomizer Low Alarm
Temperature Protection
Unit too hot
Low Power Alarm
If the resistance of the coil is lower than 0.1 ohm in VW mode or 0.05 ohm in VT mode,
the display will show “Atomizer Low”.
If the temperature of the atomizer coil is above the temperature you set in VT mode, the unit will display “Temp Protection”.
When the temperature of the device increases above 70°C, the power turns off and the display will read “Device Too Hot”.
If the battery voltage drops below 3.1V, the device indicates “Battery Low”. If you continue to
hold down the fire button, the unit displays “Battery Low Lock” and switches itself off. Charge
the battery again to unlock the device.

Related product manuals