PY500AC SLIDING GATE OPERATOR
11
positions or during opening.
� Open
Open
Open
Open priority:
priority:
priority:
priority: T he gate will return to open if press ‘ OPEN
’
button of external button switch during
closing.
�
�
�
� Limit
Limit
Limit
Limit switch:
switch:
switch:
switch: T he switch is used to accurately stop the gate in the opened and closed positions.
If the gate stops at opened position when the limit switch is reached, the gate will not move if you
press ‘ OPEN
’
button.
If the gate stops at closed position when the limit switch is reached, the gate will not move if you
press ‘ CLOSE
’
button.
�
�
�
� The device is installed with a thermal protector, the thermal protector will switch off the motor
automatically in case of the temperature is higher than 120 ° C and switch on the motor automatically
when the temperature is lower than 85 ° C ± 5 ° C.
9.
9.
9.
9. Maintenance
Maintenance
Maintenance
Maintenance
�
�
�
� Check the door once a month. The door should be carefully checked for balance. The door must be
in good working order .
�
�
�
� We suggest for safety reasons, photocells be used on all gates.
�
�
�
� Disconnect from mains supply before replacing bulb.
�
�
�
� Be sure to read the entire manual before attempting to perform any installation or service to the door
operator.
�
�
�
� Our company reserves the right to change the design and specification without prior notification.
10.
10.
10.
10. Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Trouble Possible cause s Solutions
The door fails to open
and close. LED display
does not light.
1. Power is OFF
2. Fuse burn
1. Make sure that power is ON.
2. Replace fuse.
The door can open, fails
to close.
1. Infrared beam is obstructed.
2.Infrared photocell function is
enable, but the photocell has not
been installed.
1. Remove obstructions.
2.Make sure the infrared
photocell function is disable.
Remote transmitter does
not work.
1. Battery level may be low
2. Transmitter code is lost
1. Replace the battery inside the
transmitter.
2. Re -program the transmitter.
The transmitter operating
distance is too short.
Battery level may be low. Replac e battery .
11.
11.
11.
11. Packing
Packing
Packing
Packing list
list
list
list
After receiving the gate operator, you should make an unpack-inspection, in which you should check
whether the product was damaged. If you have any problem please contact our dealer. You should find
the following items in our standard packing: