Safety Instructions
General Safety Instructions
Please read the safety instructions carefully before installation, use or maintenance.
The actuator only complies protection class IP67 (according to IEC 60529), if the device is properly
connected.
Improper use may be hazardous.
This product is not a safety device and may not be used as such.
Never put your hands/body parts or other objects into ports of mounted valves. The rotating motion can
cause serious injuries or damages.
Correct transport, proper storage and installation, and proper use and maintenance, are essential for
reliable and error-free operation. The product may not function properly as a result of dirt, wear, damage
(for example, by dropping) or improper use. Therefore, the product should not be used in applications
where a malfunction can cause danger or damage.
Check the compatibility of the valve, temperature and other operating conditions with the materials and
specifications of the product. It is the responsibility of the user to select the right product for the
application.
Never exceed the limits for torque, temperature or voltage as indicated on the product and/or in the
technical documentation.
It is not allowed to change the construction of this device.
Beware of electric shock, burnings or other injuries when working with electrical equipment.
It is recommended to install the actuator in a dry environment. In moist environments, make sure that no
moisture can penetrate the actuator. Make sure the actuator is not in contact with or in the vicinity of
flammable materials. Ensure that the product is protected from frost. Frost may damage the product
and/or block the moving parts, causing the electric ball valve to malfunction.
Maintenance may only be performed when the system is not pressurized, electrically disconnected and
cooled down.
Turn off the power supply before performing any work on the actuator to prevent the risk of electrical
shock and to prevent activation of the actuator.
The product is only safe when properly installed and operated by qualified persons.
Ensure a controlled commissioning after installation or maintenance.
Improper installation can permanently damage the actuator or lead to dangerous situations.
Compliance
The actuators are CE marked and comply with the LVD Directive (2006/95/EC) and EMC Directive
(2004/108/EC), provided that the cables and connectors are properly connected.
Intended Use
The AG-5-actuator can be applied to rotary type valves that require quarter-turn operation, such as 2-way or 3-
way ball valves and butterfly valves. Common applications include ventilation, heating systems, solar water
heaters, irrigation systems and industrial equipment.
Duty Cycle
The AG-5-series can be used for continuously for 30 minutes (S2 30 min according to IEC 60034-1), after this
period the actuator must cool down to ambient temperature. High loads and long operating times may reduce