NXU-2B Operations Manual
4-4
4.5.2 Serial or Telnet Connection Control
When using the serial port (in command mode) or Telnet, the user may disconnect a client from
a server by typing:
DISC
A connection may be made to a server by typing:
CONN <IP address>
The status of these commands may be viewed by typing:
STAT
STAT returns the following responses:
CON <IP address> The unit is connected to an NXU-2B at address <IP address>
DIS The unit is not connected
ATT <IP address> The unit is attempting a connection to <IP address>
Depending upon the characteristics of the network, the CONN and DISC commands may not
take effect immediately. In order to determine when a CONN or DISC command has
completed, issue the STAT command repeatedly to poll the status of the connection.
End of Section Four