1. Operation
7
1.4 Operational Description
y In this section the basics of operation are explained.
y
The operations can be performed on the Main Control Board of the Recording Control Unit. (To
use the Recording Control Unit, the front door has to be unlocked and opened.)
1.4.1 To Stop Recording Data onto the Protective Capsule Unit
ATTENTION
Do not stop recording data into the Protective Capsule Unit unless any of the
followings is arisen.
y The vessel is mooring in a port for maintenance
y The vessel is laid up
y Because of marine accident, it is impossible to continue the voyage
1) Press the REC STOP SWITCH on the Main Control Board.
2) The REC LED on the Main Control Board blinks.
3) After about a minute, the blinking REC LED on the Main Control Board and RECORDING
LED on the Operation Panel Unit are turned off and the recording of the data onto the
Protective Capsule Unit stops.
4) When the Recording Control Unit stops recording to the Protective Capsule Unit, the
Recording Alarm is generated. (Error code: 22__)
5) When the Recording Control Unit starts recording to the Protective Capsule Unit, the
Recording Alarm is canceled. (Error code: 22__)
1.4.2 To Restart Recording Data onto the Protective Capsule Unit
ATTENTION
Once recording is halted while in port or dock, make sure to restart
recording when leaving the port. Otherwise, no data is recorded even when
an accident has occurred.
1) Press the REC START SWITCH on the Main Control Board.
2) The REC LED on the Main Control Board lights up.
3) The RECORDING LED on the Operation Panel Unit lights, and the recording of the data
onto the Protective Capsule Unit starts.
4) When the Recording Control Unit starts recording to the Protective Capsule Unit, the
Recording alarm becomes normal.
1.4.3 Backing Up the Data of the CF CARD
1) Make sure that the CARD LED on the Main Control Board is on.
2) Press the CARD STOP SWITCH on the Main Control Board.
3) The CARD LED on the Main Control Board blinks for about 5 seconds.
4) Make sure that the CARD LED on the Main Control Board is turned off. And press the CF
CARD EJECT BUTTON.