2. Specification 
 
29 
c) Bridge audio input: 
1) Input channel:  up to 9 (channels) 
2) Input sensitivity:    6kHz 
3) Recording interval:  continuous (1 audio file / minute) 
d) VHF communications input (audio): 
1) Input channel:  up to 3 (channels) 
2) Input sensitivity:    3.5kHz 
3) Input level:  0 dBm  600-ohm  balance 
4) Recording interval:  continuous (1 audio file / minute) 
e) Radar image data input (input of No1. X band radar is recommended): 
1) Input channel:  2 (channels) 
Auto selection of a radar image from both channels 
  (If the radar is of JRC make, automatic selection of 
on-operation radar is possible.) 
2) Input interface:    analog RGB/Hs/Vs 
- RGB:  0.7Vp-p (video signal) 
- Hs:  TTL 
- Vs:  TTL 
3) Resolution:  640 x 350 – 1600 x 1200 pixel (conforms to VESA 
DMTS) 
4) Refresh rate:  60 - 85 Hz (conforms to VESA DMTS) 
(Resolution 1600 x 1200 pixel 60Hz only) 
5) Recording interval:  1 image every 15 seconds 
f) Recording data backup:   
1) Media:    CF card   
(Adapter for PCMCIA type-2 is attached to the RCU.) 
2) Storage capacity:    2.0GB 
g) Blackout processing:   
      1) Recording duration:  2 hours while blackout 
  (during the blackout, only the conversation in the 
bridge is recorded) 
2) Restoration time required: less than 1 minute 
  (Recovery time from blackout operation to normal 
operation on restoration of ship’s generator.) 
h) GPS select signal input:   
1) Interface:  Dry (voltage free) contact closure 
(Commonly used with External Contact Input ) 
2) Operation:  Recording GPS selection (active open/close) 
i) RADAR select signal input:  (Only JMA-9900, JMA-900M, JMA-5300 
1) Interface of JRC radar:  IEC61162-1 (RS-422) 
2) Operation of JRC radar:  Active radar selection by JRC original sentence 
3) Interface of other radar:  Dry (voltage free) contact closure 
(Commonly used with External Contact Input ) 
4) Operation of other radar:  Recording RADAR selection by dry contact closure 
(active open/close) 
j) External Contact Input (dry contact): 
1) Number of input:  maximum 3 dry contacts (voltage free) 
(Commonly used with the input signals which select 
RADAR or GPS.) 
2) Output sentences:  Registers sentences at the time of their making and 
opening