CONFIGURATION AND SPECIFICATIONS
1-6
1.3 Specifications
1.3.1 JHS-183 Automatic Identification System
(1) General Specification
Frequency range 156.025MHz to 162.025MHz
Default channel AIS1: 161.975MHz, AIS2: 162.025MHz
Channel spacing 25kHz
Frequency accuracy
Within ±3×10
-6
Type of emission G1D (F1D), G2B (F2B)
Type of modulation GMSK, FSK
Output power 12.5W/1W
Type of display 4.5-inch FSTN LCD, 128 x 64dot
keyboard 12 keys
Back-light LCD and keyboard
Dimmer control Bright, Medium1, Medium2, Off
Compass safe distance NTE-183; Standard compass 0.4m, Steering compass 0.2m
NCM-983; Standard compass 0.5m, Steering compass 0.3m
NQE-5183; Standard compass 0.7m, Steering compass 0.5m
NBD-577C; Standard compass 0.8m, Steering compass 0.5m
Performance criteria
Power voltage Typ. 24VDC, 19 - 35VDC
Current consumption
24VDC Input
3.0A max. (when transmitting),
1.0A max. (when receiving)
Operating temperature range AIS transponder (NTE-183) -25°C to +55°C
AIS controller (NCM-983) -15°C to +55°C
Storage temperature range -15°C to +55°C (exposed equipment; -25°C to +70°C)
Humidity resistance No abnormality after standing 4 hours in +40°C, 93% RH
Vibration resistance (3 axes)
2 Hz - 5 Hz to 13.2 Hz: : Full amplitude ±1 mm±10%
13.2 Hz to 100 Hz: : Maximum acceleration 7 m/s
2
fixed
No abnormality after testing resonance points or at 30 Hz for more
than 2 hours
Protection rating AIS transponder (NTE-183): IP56
AIS controller (NCM-983): IP55 (In case optional cable is not used.)
Dimensions and mass
AIS transponder (NTE-183)
145mm(W) x 1270mm(H) x 145mm(D)
[including VHF antenna]
,
approximately 2.6kg
AIS controller (NCM-983)
142mm(W) x 142mm(H) x 115mm(D), approximately 2.1kg
(2) Communication ports
(2.1) Communication ports
The communication ports using the attached cable (CFQ-9183A) are as follows.
Sensor data input ports
SENSOR1 / SENSOR2
Two input ports meet the requirements of IEC 61162-1 and 61162-2
GNSS differential correction data
input port
ITU-R M.823-2 1port
External display equipment
communication ports (AUX)
IEC61162-2 1ports
Pilot plug IEC61162-2 1port
Network(LAN) IEC61162-450 1port