Chapter 4 MAINTENANCE
4.3 PERFORMANCE CHECK
4-11
4
INSTRUCTION MANUAL
4.3.7 LINE MONITOR
Serial communication data can be seen on the built-in Line monitor.
Line monitor can be used to make sure that the serial data are received properly.
"Line Monitor" operations
1 Open Test - Line Monitor .
"Line Monitor" menu appears.
Receive Data: The received serial communication data are displayed.
Send Data: The transmitted serial communication data are displayed.
Soft key 1: GPS NMEA1 Gyro/Compass NMEA2
Keyboard Scanner
Press the soft key 1 to select the port for serial communication data.
Soft key 2: ASCII Binary
Press the soft key 2 to switch the display.
Soft key 3: Stop Play
Press the soft key 3 to stop/start scrolling.
Soft key 4: Clear
Press the soft key 4 to clear all listed serial communication data.