EasyManua.ls Logo

JRC JMA-2354 - Chapter 7 Specifications; 7.1 General System Specifications

JRC JMA-2354
210 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 SPECIFICATIONS
7.1 GENERAL SPECIFICATIONS
7-1
7
INSTRUCTION MANUAL
Chapter 7 SPECIFICATIONS
7.1 GENERAL SPECIFICATIONS
(1) Class of Emission P0N
(2) Display Raster Scan, PPI
(3) Screen 10.4-inch Monochrome LCD, VGA (640 480 dots)
(4) Range Scale 0.125, 0.25, 0.5, 0.75, 1.5, 3, 6, 12, 24, 48, 72 NM
(6 kw for 72 NM )
User can add 1, 2, 4, 8, 16 or 32NM.
* Off Center is not available at maximum range.
(5) Range Resolution Less than 30m
(6) Minimum Detective Range Less than 40m
(7) Range Accuracy Less than 1% of the maximum distance of the range scale
in use or less than 15m whichever is larger
(8) Bearing Accuracy Less than 1°
(9) Bearing Indication Head-up, North-up, Course-up
(10) Ambient Condition
Standards IEC60945 Ed.4.0
Temperature
Scanner Operation: -25 to +55°C / Storage: -25 to +70°C
Other Unit except Scanner
Operation: -15 to +55°C
Relative Humidity
Entire Unit +40°C, 93%
Vibration
Entire Unit 2 to 13.2 Hz, amplitude±1mm
13.2 to 100 Hz 0.7 G
Velocity of the wind 51.5m/s (100kn)
(11) Power Supply Input DC+24V (Cable length of 30m or less)
DC+12V (Cable length of 20m or less)
(12) Power Consumption In calm wind:
Approx. 60W (4kW)
Approx. 85W (6kW)
Maximum (Velocity of the wind: 100kn):
Approx. 60W (4kW)
Approx. 180W (6kW)
(13) Pre-heating Time Approx. Within 1min30sec

Table of Contents