6 Set 11. [Length L] (length left) and 12. [R] (right).
Adjust the length of the parallel index line by changing the positions of endpoint 1 (Length L) and
endpoint 2 (R).
Define endpoint 1 as the point on the left side when PI centre is viewed from the own ship and
endpoint 2 as the point on the right side.
Set the mode to the endpoint change mode by pressing the [VRM] dial and turn the [VRM] dial
to change the position of an endpoint.
Clockwise: + (Direction from the centre of PI to outside)
Counterclockwise: - (Direction towards the centre of PI)
The input range is as follows.
The minimum length of a parallel index line from the left end to the right end is 2 cm.
The maximum length is double the PPI radius.
Memo
A negative value can also be set for [Length].
In the case of the left end, the left direction from the centre becomes a positive value and the
right direction from the centre becomes a negative value.
In the case of the right end, the right direction from the centre becomes a positive value and
the left direction from the centre becomes a negative value.
Whenever the unit display switching button on the right side of [length] is clicked on, the unit
(NM/km/sm) of the numeric value that is displayed is switched.
Memo
NM denotes nautical mile, sm denotes statute mile, and km denotes kilometre.
Setting parallel index lines consecutively
When [Sequential] is checked and [Screen Fix] or [L/L Fix] is selected at floating mode switching, the
parallel index lines to be set are changed in the sequence of Index Line12•••81••• and setting
can be performed consecutively.
Memo
The index lines that are set to be hidden by selecting [View] - [Tools] on the menu are skipped
during operation.
Endpoint 2
Endpoint 1
Change the length of endpoint 2
Centre of PI