18-21 Section 18 Specifications
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
付録
18.20 Target Tracking
FUNCTIONAL SPECIFICATION
Acquisition
Acquisition Mode
Manual/AUTO (AUTO mode uses AUTO-acquisition Zone)
Manual Cancellation
Any one Target or All targets at once
Acquisition Range
0.1NM to 32NM (Available in all range scale)
Tracking
Number of Target
30 targets (Option: up to 100 targets)
Tracking Range
0.1NM to 32NM (Available in all range scale)
View
Motion mode
TM (True Motion) / RM (Relative Motion)
Azimuth mode
North UP, Head UP, Course UP
Vector mode
True / Relative Display
Vector Length
Variable, 1 to 120 min. (1min. step)
Past Position
True / Relative Display
Number of Dots --- 10 points
Display Interval Time --- 0.5 / 1 / 2 / 4 min
Display range: 0.1NM, 0.2NM, 0.5NM, and 1NM
Time to Display Vector
within 1 minute
Time to Stabilise Vector
within 3 minutes
Alarm
AUTO-acquisition Zone (AZ)
2 (sector)
Setting range
1NM to 32NM
Alarm Indication
Symbol on Display, Visible/Audible Alarm
Safe Limits (CPA/TCPA)
CPA LIMIT
0.1 to 9.9NM
TCPA LIMIT
1 to 99 minutes
Conditions
Safe Target
CPA > CPA Limit
0 > TCPA
TCPA > TCPA Limit
Dangerous Target
CPA
CPA Limit
0 TCPA TCPA Limit
Lost Target
Symbol on Display, Visible/Audible Alarm
Alert Indication
Safe Target
Colour: White, Alert: OFF, Buzzer: OFF
Dangerous Target
Colour: Red, Alert: ON, Buzzer: ON
Data Indication
Target Data
Simultaneous display for 10 targets (26-inch screen)/4 targets (19-inch
screen)
True Bearing, Range, True Course, True Speed, CPA, TCPA, BCR,
BCT
Own Ship's Data
Course and Speed
Trial Manoeuvre
Manual Setting
Trial Course
0° to 359.9°
Trial Speed
0 to 100 kn
Another ship track 100 targets. 4000 points per one target can be displayed.
(Own ship track and marks are another.)
Display color : 10 colors
(The display color of each target can be set.) (The display color of
all targets can be set by the batch. In this case, the display color is
one color.)
Interval of save : 3/5/10/30 sec, 1/3/5/10/30/60 min,
0.1/0.2/0.3/0.5/1/3/5/10 NM
Possible to storage in memory card (Option).
Accuracy of Display
System Failure
Speed Input
Complied with IMO Requirements
Visible / Audible Alarm
Manual / AUTO (LOG)