OPERATION AT EMERGENCY (MANUAL ACTIVATION)
Turn the stopper to arrow mark direction breaking the stopper pin.
Turn ON the selector switch. Then, the indication lamp flashes and distress signal is transmitted
for over 48 hours. After setting, turn the stopper back to original position to keep switch ON.
Operation of the selection switch is available by opening the hatch of the automatic release
mounting bracket.
Stopper pin
Selector switch
Stopper
Stoppe
r
Stopper pin
Selector switch
Selector switch
Hatch
Fig.3 Operation procedure at emergency