5-3
5
B-(3) Homing signal
Transmitting frequency 121.5 MHz ± 6.075 kHz
Peak radiation power 50 mW ±3 dB
Modulation AM
Modulation frequency 300 Hz to 1600 Hz
Modulation repetition cycle 2 Hz to 4 Hz
B-4) Battery
Model Model P-35
Type Lithium Manganese dioxide pack
Composition Serial 3 cells
Voltage Nominal 8.4 V
Capacity 10.4 Ah
Validity period 5 years after installation
B-(5) Activation
Automatic
The Satellite EPIRB starts to transmit the distress signal upon detection of
water after release of Satellite EPIRB from the automatic release bracket.
Manual
The Satellite EPIRB starts to transmit the distress signal by turning selector
switch to “ON”.