– 78 –
2) Alternate vertical change base
1. Remove top cover.
2. Remove two return springs
of alternate vertical change base.
3. Loosen setscrews
of felt clamp to remove felt clamp
.
4. Apply JUKI grease A to felt
.
5. Apply JUKI grease A to sliding surfaces of alternate vertical change base and feed conversion link.
6. Set felt clamp
to alternate vertical change base, and x it with setscrews
of felt clamp.
7. Attach two return springs
of alternate vertical change base.
8. Attach top cover.
3) Horizontal feed change base
1. Remove rear cover.
2. Loosen setscrews
of felt clamp to remove felt clamp
.
3. Apply JUKI grease A to felt
.
4. Apply JUKI grease A to sliding surfaces of horizontal feed change base and feed conversion link.
5. Set felt clamp
to horizontal feed change base, and x it with setscrews
of felt clamp.
6. Attach rear cover.