EasyManua.ls Logo

JUMO DICON 501 - User Manual

JUMO DICON 501
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
JUMO DICON 401/501
Universal Profile Controller
Universal Profile Generator
B 703580
Operating Manual
2013-10-01/00370044
Type 703585/1... Type 703580/0...
Type 703585/2...

Table of Contents

Other manuals for JUMO DICON 501

Question and Answer IconNeed help?

Do you have a question about the JUMO DICON 501 and is the answer not in the manual?

Summary

1 Introduction

2 Identifying the Instrument Version

2.1 Type Designation

Guide to understanding the model number and its components.

3 Installation

4 Electrical Connection

4.1 Installation Notes

Important guidelines for safe and compliant electrical installation of the instrument.

4.2.1 Type 703580 Connection Diagrams

Visual representations of electrical wiring for Type 703580.

4.2.2 Type 703585 Connection Diagrams

Wiring diagrams for Type 703585, covering interfaces, outputs, and inputs.

5 Operation

5.1 Displays and Keys

Identifies and describes the instrument's displays, status indicators, and control keys.

5.5.3 Automatic Operating Mode (Program Run)

Details how to start, alter, and hold profile programs during automatic operation.

6 Profile Program Start

7 Profile Program Editor

7.1 General

Overview of profile program creation, including segments, setpoints, times, and contacts.

10 Configuration Level 1

Configuration Sections Overview

Lists main configuration sub-sections (Inputs, Outputs, etc.) and their page references.

10.1 Controller Configuration

Configuration of controller type (PID, PI, etc.) and control direction (direct/inverse).

10.2 Limit Comparators Configuration

Explains limit comparator functions (Ik1-Ik8) and their basic setup.

10.5 Profile Controller Configuration

Configuration of profile controller function, restart behavior after power failure.

10.6 Maths and Logic Module Configuration

Configuration options for mathematics functions (ratio, difference) and logic functions.

10.8 Logic Functions Configuration

How to assign functions to logic inputs, limit comparators, contacts, and program signals.

10.9 Interface Configuration

Configuration of communication interface parameters like protocol, baud rate, parity, and stop bits.

11 Optimisation

11.1 Self-optimisation

Explains the process of self-optimisation for PID/PI controllers and how to start it.

11.2 Checking the Optimisation

How to check controller response after optimisation and identify maladjustments.

11.3 Fuzzy Parameters

Configuration and effect of fuzzy logic parameters (Fc1, Fc2) on controller performance.

13 Interfaces

14 Accessories

14.2 Setup Program with Commissioning Software

Information on the setup program for configuration, parameter transfer, and graphical display.

15 Appendix

15.2 Alarm Messages and Display Priorities

Comprehensive table of alarm messages, their causes, assignments, and error handling procedures.

Summary

1 Introduction

2 Identifying the Instrument Version

2.1 Type Designation

Guide to understanding the model number and its components.

3 Installation

4 Electrical Connection

4.1 Installation Notes

Important guidelines for safe and compliant electrical installation of the instrument.

4.2.1 Type 703580 Connection Diagrams

Visual representations of electrical wiring for Type 703580.

4.2.2 Type 703585 Connection Diagrams

Wiring diagrams for Type 703585, covering interfaces, outputs, and inputs.

5 Operation

5.1 Displays and Keys

Identifies and describes the instrument's displays, status indicators, and control keys.

5.5.3 Automatic Operating Mode (Program Run)

Details how to start, alter, and hold profile programs during automatic operation.

6 Profile Program Start

7 Profile Program Editor

7.1 General

Overview of profile program creation, including segments, setpoints, times, and contacts.

10 Configuration Level 1

Configuration Sections Overview

Lists main configuration sub-sections (Inputs, Outputs, etc.) and their page references.

10.1 Controller Configuration

Configuration of controller type (PID, PI, etc.) and control direction (direct/inverse).

10.2 Limit Comparators Configuration

Explains limit comparator functions (Ik1-Ik8) and their basic setup.

10.5 Profile Controller Configuration

Configuration of profile controller function, restart behavior after power failure.

10.6 Maths and Logic Module Configuration

Configuration options for mathematics functions (ratio, difference) and logic functions.

10.8 Logic Functions Configuration

How to assign functions to logic inputs, limit comparators, contacts, and program signals.

10.9 Interface Configuration

Configuration of communication interface parameters like protocol, baud rate, parity, and stop bits.

11 Optimisation

11.1 Self-optimisation

Explains the process of self-optimisation for PID/PI controllers and how to start it.

11.2 Checking the Optimisation

How to check controller response after optimisation and identify maladjustments.

11.3 Fuzzy Parameters

Configuration and effect of fuzzy logic parameters (Fc1, Fc2) on controller performance.

13 Interfaces

14 Accessories

14.2 Setup Program with Commissioning Software

Information on the setup program for configuration, parameter transfer, and graphical display.

15 Appendix

15.2 Alarm Messages and Display Priorities

Comprehensive table of alarm messages, their causes, assignments, and error handling procedures.

JUMO DICON 501 Specifications

General IconGeneral
Protection classIP65
Power supply110 to 240 V AC +10/-15 %, 48 to 63 Hz or 20 to 30 V AC/DC
Input channels4
Output channels4
WeightApprox. 250 g
DisplayLED
OutputsUp to 4
Control typePID
CommunicationRS-485
Communication interfaceModbus RTU
Operating temperature range-10 to 55 °C
Dimensions96 mm x 48 mm x 130 mm (3.78 in x 1.89 in x 5.12 in)

Related product manuals