Parameters Setting options,
Default setting
Explanations
Disabling func-
tion (restraint
guidance)**
Deactivated, continu-
ously ON, continuously
OFF, for fixed time ON/
OFF
Default setting: deactiv-
ated
The disabling function switches the load
output to the desired status and blocks it
against control by the motion sensor, ex-
tension operation, time programs and
wireless control with the app and other
JUNG HOME devices. The lock applies
for an adjustable time or until the dis-
abling function is deactivated again
** Available by update in the future: You can find notes on updates and dates at
www.jung.de/JUNGHOME
Additional settings for dimming/DALI inserts Lj
Parameters Setting options,
Default setting
Explanations
Switch-on delay 0 s (off) ... 240 min
Default setting: off
Switches on the load after a switch-on
command, delayed by the value. Re-
peated switch-on commands during the
current delay do not start the delay again.
If the load has not yet been switched on
due to the delay, the load remains
switched off when a switch-off command
arrives.
Switch-off delay 0 s (off) ... 240 min
Default setting: off
Switches off the load after a switch-off
command, delayed by the value. Re-
peated switch-off commands during the
current delay restart the delay time. If the
load has not yet been switched off due to
the delay when a switch-on command
comes, then the load will remain on.
Switch-off warn-
ing
Off, on
Default setting: off
If the switch-off warning is switched on,
the light is not switched off immediately
after the run-on time (load) has elapsed.
The light is first dimmed to minimum
brightness within 30 seconds. The run-on
time is thereby prolonged by approx.
30 seconds. If, during the switch-off warn-
ing, a movement is detected by a linked
JUNG HOME sensor cover or the warning
is switched on again by operating an ex-
tension or by a linked JUNG HOME oper-
ating cover, the run-on time will be restar-
ted and the light switched back to the
switch-on brightness.