Parameters Setting options,
Default setting
Explanations
Run-on time
(load)
0 s (off) ... 240 min
Default setting: off
Ensures that the load is switched off after
the set run-on time expires instead of re-
maining permanently switched on after a
switch-on command.
If a movement is detected by a linked
JUNG HOME sensor cover during the
run-on time or the operating cover is
switched on again by operating an exten-
sion or a linked JUNG HOME operating
cover, the run-on time is restarted and the
light remains on.
The load can be switched off early during
the current run-on time only if the "Manual
switch-off during run-on time" parameter
is set to "On" or a disabling function (con-
tinuously off) is started.
Manual switch-
off during run-
on time
Off, on
Default setting: on
If this parameter is set to "On", it will be
possible to switch off the load manually
during the current run-on time (load).
For automatic staircase lighting controlled
by JUNG HOME operating and/or sensor
covers, this parameter should be set to
off to prevent the light from being able to
be switched off by a second person.