Parameters Setting options,
Default setting
Explanations
Position when
the mains
voltage re-
turns**
0 ... 100% Position of the Venetian blind, shutter or
awning after the mains voltage returns.
Note: Applies only if the "stored position"
was selected for "Behaviour after mains
voltage returns".
Note: With JUNG HOME, 0% corres-
ponds to "0% closed", the "upper posi-
tion" or a completely retracted Venetian
blind / awning / shutter.
With JUNG HOME, 100% corresponds to
"100% closed", the "lower position" or a
completely extended Venetian blind /
awning / shutter.
Slat position
when the mains
voltage re-
turns**
0 ... 100% Slat position after the mains voltage re-
turns.
Note: Applies only if the "stored position"
was selected for "Behaviour after mains
voltage returns".
Disabling func-
tion (restraint,
lock-out protec-
tion, wind
alarm)**
Deactivated, lock-out
protection, restraint,
wind alarm
Duration: continuously or
fixed time
Default setting: deactiv-
ated
Depending on the disabling function, the
shutter or the awning is locked in the cur-
rent position or a specific position is ap-
proached first when the Venetian blind is
activated.
An active disabling function prevents ex-
tension operation, time programs and
wireless control with the app and other
JUNG HOME devices. The lock applies
for an adjustable time or until the dis-
abling function is deactivated again.
Lock-out protection: remains in the cur-
rent position
Restraint guidance: approaches ad-
justable position 0% ... 100%
Wind alarm: approaches adjustable posi-
tion 0%
** Available by update in the future: You can find notes on updates and dates at
www.jung.de/JUNGHOME
JUNG HOME push-button 1-gang, JUNG HOME push-button 2-gang
25 / 26
32405203 24.02.2023
J0082405203