Common parameters
Function Standard
Setting
Range
Reduction brake
52
(0.52 m/s
2
)
52
(0.52 m/s
2
)
Service Brake
125
(1.25 m/s
2
)
125 - 330
(1.25 - 3.3 m/s
2
)
Body protection acceleration
104
(1.04 m/s
2
)
56 - 104
(0.56 - 1.04 m/s
2
)
Standard travel program 2 0 - 3
Battery parameters
No. Function Setting
range
Standard
setting
Comments
1377 Battery type
(normal / high
performance / dry)
0 - 5
7
9
1 0 = Normal (wet)
1 = High performance
(wet)
2 = Dry (maintenance-
free)
3 = US "Flat Plate" type
4 = US "Pallet Pro" type
5 = US "Tubular Plate"
type
7 = Exide GF12063Y
(Dry battery)
9 = XFC
(Special battery)
1389 Discharge monitor
function
0/1 1 0 = not active
1 = active
NOTICE
Battery damage
The battery, charger (charge characteristics) and battery parameters must match
each other, otherwise damage may result.