EasyManuals Logo

Jungheinrich TFG 435s User Manual

Jungheinrich TFG 435s
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #199 background imageLoading...
Page #199 background image
03.13 EN
198
4.14 Restoring the truck to service after maintenance and repairs
Procedure
Thoroughly clean the truck, see "Cleaning" on page 194.
Lubricate the truck according to the lubrication schedule, see "Lubrication
Schedule" on page 160.
Clean the starter battery, grease the terminals and connect the starter battery.
WARNING!
Faulty brakes can cause accidents
As soon as the truck has been started, test the brakes several times.
XReport any defects immediately to your supervisor.
XTag out and decommission the faulty industrial truck.
XOnly return the truck to service when you have identified and rectified the fault.
Start up the truck, see "Preparing the Truck for Operation" on page 65.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich TFG 435s and is the answer not in the manual?

Jungheinrich TFG 435s Specifications

General IconGeneral
BrandJungheinrich
ModelTFG 435s
CategoryForklifts
LanguageEnglish

Related product manuals